Products Purchase Support Download    News About

Support - DynaComm Connectivity Series® for Windows CE 2.0

DynaComm Connectivity Series® for Windows CE 2.0


Technical Profile


Contents


Related Support Documents
· DCS/CE 2.0 FAQ
· Telnet Troubleshooting Guide
· White Papers

I. Overview

A. Release History


II. Functionality

A. Platforms Supported

B. Basic Functionaliy

1. Emulations

2. Connectors

3. File Transfer Protocols

4. Tools/User Interface

a. Attribute Mapper

b. Stylus Properties

5. Documentation/Help

C. Enhancements and Related Products

1. Client Options

 

III. Technical Specifications

A. Minimum Recommended System Requirements

B. Installation

1. General

2. Installation Procedure

3. Custom Installation Procedure

C. Registry Modifications

D. Directory Structure

E. Icons

F. Configuration/Initialization Files

 

I. Overview

This Technical Profile is intended to provide in-depth information about DynaComm Connectivity Series for Windows CE (DCS/CE) features, specifications and configuration. Information in this document pertains to the most current release of the product (see the Product Release History below).

DynaComm Connectivity Series for Windows CE (DCS/CE) Release 2.0.0.0

DCS/CE is designed to provide users with the flexibility to integrate host mainframe and minicomputer systems with a handheld PC-based Windows environment. Optional client emulation components including TN3270, TN5250, Tandem 6530, and AT&T 4425 are fully integrated into the product when installed.

 

A. Release History

 

 
Version Release Date Release Status
DCS/CE 2.0.0.0 September 15, 1998 As Is
DCS-H/PC 1.0.0.0 June 15, 1998 As Is
 

Return to top

 

II. Functionality

 

A. Platforms Supported

  • Windows CE 2.0 and greater

Return to top

 

B. Basic Functionality


1. Emulations -- standard standard in the DCS/CE Core Product

  • ADDS VP/60
  • ANSI BBS (with SCO ANSI extensions)
  • AT&T 605/705
  • Digital VT-52, 100/ 102, 220, 320 and 420
  • TeleVideo 925/950
  • Wyse 50/60

2. Connectors -- standard in the DCS/CE Core Product

  • Direct Serial
  • Modem (TAPI)
  • Telnet (TCP/IP)

3. File Transfer Protocols -- standard in the DCS/CE Core Product

Return to top

 

4. Tools/User Interface

 

DCS/CE provides users with several tools to customize their workspace and automate common tasks.

 

a. Attribute Mapper

 

 
Purpose: Allows users to create and save custom color maps which associate host character attributes to local display colors.
Accessed via: Session: Properties: Emulations: Attributes
Configuration: Host character attributes are displayed with their current video characteristics. Users can modify the foreground and background colors and assign display attributes such as Blink and Reverse Video.
Settings stored: Color maps are saved in the application subdirectory with the extension .acm. The name of the color map assigned to the current session is stored in the corresponding session file under the [EMULATION] heading.
Defaults: Each emulation shipped with the Core Product or with Client Options has a default color map associated with it. If the user wishes to use a different color map than the default, existing .ACM files can be loaded from the Map File drop-down list box.
Scope: Color map settings apply only to the session for which they are selected.

 

Return to top

 

b. Stylus Properties

 

 
Purpose: Allows the user to configure custom stylus click functionality which can be saved to a session file.
Accessed via: Session: Options: Stylus
Configuration:

The stylus can be set to: make box selection, make line selection, send character, select word, send word, send selected text, or move cursor to stylus point. These tasks can be set to execute either with a single or double click of the stylus, with or without a modifier key depressed.

Settings stored: All settings are stored in the session file in the application subdirectory.
Defaults: The display module provides the default settings for this option.
Scope: Stylus Properties settings apply only to the session for which they are selected.

 

Return to top

 

5. Documentation/Help

 

All DCS/CE documentation is available online. The following table lists the documents and the associated help files, which are located in the DCS/CE installation directory.

Please Note: All help files are installed on the desktop PC only to help reduce the footprint on the handheld device.

 

 
Title Help File Name
DCS/CE Help DYNACE.HLP
AT&T 4425 Client Option Help ATT4425.HLP
Tandem 6530 Client Option Help TANDEM.HLP
TN3270 Client Option Help IBM.HLP
TN5250 Client Option Help IBM.HLP
 

 

Return to top

 

C. Enhancements and Related Products

 

1. Client Options

 

DCS/CE has several Client Options—sold separately—which provide additional emulation and host connectivity capabilities when installed with the DCS/CE Core Product. Currently available Client Options are outlined below. Installation of a Client Option adds emulator and any required file transfer modules to the application subdirectory, adds any necessary color and keyboard maps, and adds the help files to the DCS/CE installation directory on the companion PC. After installation, the new emulator/file transfer(s) are integrated into the product and are available from the appropriate tab of the Session Properties dialog.

 

 
AT&T 4425 Client Option Provides AT&T 4425 terminal emulation. Online documentation is included in the file ATT4425.HLP.*
Tandem 6530 Client Option Provides Tandem 6530 terminal emulation and IXF file transfer. Online documentation is also included in the file TANDEM.HLP.*
TN3270 Client Option Provides IBM 3270 terminal emulation, IBM 3287 printer emulation and IND$FILE file transfer capability. Online documentation is also included in the file IBM.HLP.*
TN5250 Client Option Provides IBM 5250 terminal emulation and IBM 3812 printer emulation. Online documentation is also included in the file IBM.HLP.*

 

*NOTE: The help files are installed on the desktop PC, not on the Windows CE-powered device.

 

Return to top

 

III. Technical Specifications

 

A. Miniumum Recommended System Requirements


  • DCS/CE currently supports the MIPS and SH3 processors running Windows CE 2.0 and greater. Additional processors will be added as the market dictates.
  • 8 megabytes of RAM
  • 8 megabytes of ROM (required with Windows-based Terminals)

Product installation sizes by processor type (in bytes):

 

 
Module MIPS SH3
DCS/CE Core Product 2,608,380 2,174,716
AT&T 4425 Client Option 98,304 78,336
Tandem 6530 Client Option 300,032 227,328
TN3270 Client Option 255,488 200,704
TN5250 Client Option 229,888 180,736

 

Return to top

 

B. Installation


1. General

 

DCS/CE ships on five 3.5 inch floppy diskettes.

 

2. Installation Procedure


The installation of DCS/CE performs the following main functions, in this order:

  1. Checks the Registry to see if a previous version of DCS/CE is installed. If a previous version is found, it launches the component install/uninstall SETUP program.
  2. Displays License Agreement and retrieves user registration data.
  3. Allows the user to select a complete, compact or custom installation, and creates a new program directory or lets user select existing directory.
  4. Prompts for a program folder name, and copies the user files.
  5. Prompts user for seven diskettes (if applicable).
  6. Modifies the Windows Registry (see below).
  7. Creates program folders and shortcut icons if selected by user.
  8. Displays the release notes if selected by user.
  9. After installation of the DCS/CE Core Product to the desktop is completed, DCS/CE then downloads the installation files to the Windows CE-powered device through Windows CE Services.
  10. Windows CE Services asks the user to check the device to see if any further steps are necessary to complete the installation.

Return to top

 

3. Custom Installation Procedure

 

Below is a table showing the names of files that may be deleted when the corresponding connector or emulator is not required. Deleting unnecessary files will free memory for other applications.

 

 
Connectors
Connector Not Required Delete this file MIPS* SH3*
Direct Serial comdir.con 47,616 41,984
Modem comtapi.con 84,504 77,824

 

 
Emulators
Emulation Not Required Delete this file MIPS* SH3*
ADDS VP/60 addsvp60.emu 54,272 44,544
AT&T 605/705 att605.emu 224,768 173,056
TeleVideo 925/950 tv950.emu 163,840 139,776
VT-Series and AT&T 605
(see note 2 below)
vtseries.dll 144,384 109,056
VT-Series vt420.emu 160,768 132,096
Wyse 50/60 wyse.emu 156,672 126,464

 

*File size in bytes.

 

Notes:

  1. ANSI-BBS is the default emulator. As such, this file should NOT be deleted.
  2. The VT-Series and AT&T 605 emulation file (vtseries.dll) can be deleted ONLY if the VT-Series AND AT&T 605 emulations are not needed. This file is used by both the VT-Series and AT&T 605 emulations.
  3. With only the ANSI emulation and the Telnet connector installed, the smallest achievable product size is:
  • MIPS CPU: 1,184,508 bytes
  • SH3 CPU: 1,007,868 bytes

NOTE: The MFCCE20.dll must be present for DCS/CE to operate. If it is not already installed on your device, the DCS/CE installation program will automatically install it. The file size is:

  • MIPS CPU: 517,632 bytes
  • SH3 CPU: 364,544 bytes

Return to top

 

C. Registry Modifications


DCS/CE modifies the Windows Registry as noted below. This information is provided for Application Administration personnel, not the casual user. Because InstallShield is used for automatic installation and uninstallation, users have no need for this detailed information.

 

[HKEY_CURRENT_USER\Software\FutureSoft\DCSCE]

 

Settings stored here include: Telnet hostname and port settings.

 

[HKEY_LOCAL_MACHINE\SOFTWARE\CLASSES]

 

Session files (.ses) are registered with the Windows shell under these keys to create an association with DynaCE.EXE.

 

[HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\
Uninstall\DCSCEDeinstKey]

 

This entry stores the pointer to the DCS/CE Uninstall string (on the desktop PC).

 

Return to top

 

D. Directory Structure

 

 

Return to top

 

E. Icons


 
DynaCE.EXE is the DCS/CE main executable. This executable can take existing session files as command line parameters, launching the session at startup. By default, it is installed in the Windows directory.

 

Return to top

 

F. Configuration/Initialization Files

 

 
NAME TYPE DEFAULT LOCATION DESCRIPTION
Registry Entries Registry HKEY_CURRENT_USER\
Software\FutureSoft\DCSCE
See Registry Modifications above.
*.ACM BINARY Windows\ User-defined attribute/color maps for a specified emulation.
*.CAB BINARY Windows\ Uninstall files, used by Add/Remove Programs to properly uninstall Core Product or Client Options.
*.KBM BINARY Windows\ User-defined keyboard maps for an emulation.
*.SES TEXT Windows\ Session properties (connector, emulation, file transfer protocol, display, general, stylus).

 

Return to top


Purchase Contact Privacy Policy Terms of Use Sitemap Blog
© 2010 FutureSoft, Inc. All Rights Reserved

 
DynaComm i:filter | Internet Filtering | Employee Internet Monitoring | Managing Internet Access | Web Filtering | Internet Monitoring | DCS
Terminal Emulation | TN 3270 | ProComm Plus Replacement | Windows Terminal Emulation | TN 5250 | DynaComm Connectivity Series | MultiView